E.P.A. APPROVED TECHNOLOGY
The data below represent the quantity of Cryo ClearTec Particulate needed to solidify carious fuels and industrial liquids to the point at which they will pass the E.P.A. 50 PSI landfill pressure test.
PROCEDURE USED
8.1 ml, 12.2 ml, and 16.3 ml volumes of the liquids to be tested were transferred by pipette to a 50 ml. Erlenmeyer flasks and stoppered with neoprene stoppers. These test samples were allowed to come to thermal equilibrium at 65°F. To each test sample a weighed 3.0 gram sample of CCT Particulate was added and agitated. The samples were allowed to stand for 21 hours at 65°F. The samples were then subjected to a pressure test in excess of 100 PSI. The results of this work are summarized in Table 1.
FUELS RESULTS
Bunkers 1 pound sorbent to 2/3 gallon range
Jet fuel 1 pound sorbent to 2/3 gallon range
Diesel 1 pound sorbent to 2/3 gallon range
Gasoline 1 pound sorbent to 2/3 gallon range
OILS RESULTS
Light Crude 1 pound sorbent to 2/3 gallon range
Alphatic 1 pound sorbent to 1/2 gallon range
Aromatic 1 pound sorbent to 2/3 gallon range
Napthenic 1 pound sorbent to 1/2 gallon range
Cutting 1 pound sorbent to 2/3 gallon range
Transformer 1 pound sorbent to 2/3 gallon range
Motor 1 pound sorbent to 1/2 gallon range
CHLORLATED LIQUIDS RESULTS
Carbon Tetrachloride 1 pound sorbent to 2/3 gallon range
Chloroform 1 pound sorbent to 2/3 gallon range
Trichloroethane 1 pound sorbent to 2/3 gallon range
Tetrachloroethane 1 pound sorbent to 2/3 gallon range
Trichloroethelene 1 pound sorbent to 2/3 gallon range
MISCELLANEOUS LIQUIDS RESULTS
Benzene 1 pound sorbent to 2/3 gallon range
Toluene 1 pound sorbent to 2/3 gallon range
Xylene 1 pound sorbent to 2/3 gallon range
Hexane’s (Mixture) 1 pound sorbent to 2/3 gallon range
Petroleum Ether 1 pound sorbent to 1/2 gallon range
Turpentine 1 pound sorbent to 2/3 gallon range
Tricresyl Phosphate poor results, no application
Ethyl Alcohol poor results, no application
Ethylene Glycol poor results, no application